Features | ||
Versatile Input selection : DC / AC / PT-100 / Potentiometer / Resistor / Load Cell | ||
Versatile output selection : 4 ~ 20mA, 0 ~ 20mA, 0 ~ 5V, 0 ~ 10V | ||
Accuracy : ± 0.1% F.S.(others) | Surge test of 2000Vac / 1min between input / output / power | |
± 0.2% F.S.(AC) | High stability, non-flammable case(PC), high safety | |
Specifications Calibration Dimensions Connection Ordering Information | ||
Input selection : DC / AC / PT-100 / Potentiometer / Resistor / Load Cell | Surge Test : 2KVac/1min | |
Output selection : 4 ~ 20mA, 0 ~ 20mA, 0 ~ 5V, 0 ~ 10V | Input Impendence : Voltage : > 2V for 20KΩ/V; <=2V for >200MΩ | |
Accuracy : ± 0.1% F.S.(Others) | Current : >= 0.2A at 100mV; <0.2A at 1V | |
± 0.2% F.S.(AC) | Output Capability : Voltage Output : <10V | |
Zero Adjustment : <= ± 5% F.S. | Current Output : <20mA | |
Span Adjustment : <= ± 10% F.S. | Operating Temperature : 0 to 60 degree C | |
Output Ripple : <= ± 0.1% F.S. | Operating Humidity : 20~90% RH, non-condensing | |
Temperature Coefficient : 100 ppm/degree C(0 to 60 degree C) | Storage Temperature : -10 to 70 degree C | |
Output Response Time : <250 msec(0~90%) | Storage Humidity : 20~90% RH, non-condensing | |
Isolation : Input / Output / Power / Case | Installation : Socket / Plug-in | |
Insulation Resistance : > 100M OHM with 500Vdc |
Download |